Podsumowanie treści

Strona 1 - ENG – 97D S

ENMET CorporationPO Box 979Ann Arbor, MI 48106-0979Manual Part Number80003-035MCN-389, 01/21/08ENG – 97D STAND-ALONEMANUAL

Strona 2 - List of Illustrations

ENG-97D STAND-ALONEENMET Corporation85.0 WARRANTYENMET warrants new instruments to be free from defects in workmanship and material under normal use f

Strona 3 - 1.0 Introduction

PO Box 979680 Fairfield CourtAnn Arbor, Michigan 48106-0979734.761.1270 Fax 734.761.3220Returning an Instrument for RepairENMET instruments may be ret

Strona 4 - 2.0 Features

Repair Return FormMailing Address:ENMET CorporationPO Box 979Ann Arbor, Michigan 48106Phone Number: 734.761.1270FAX Number: 734.761.3220Shipping Addr

Strona 5

Table of Contents1.0 Introduction ...

Strona 6 - 3.0 Installation

ENG-97D STAND-ALONEENMET Corporation11.0 IntroductionThe ENG-97D STAND-ALONE is a single channel monitor designed to operate as a stand-alone toxic ga

Strona 7

ENG-97D STAND-ALONEENMET Corporation22.0 FeaturesSee figures 1 and 1A.Feature DescriptionEnclosurePolycarbonate, IP 65 (Shown in Figure 1) Size: 6.3

Strona 8 - 4.0 Calibration

ENG-97D STAND-ALONEENMET Corporation3Front View Side ViewFigure 1: ENG-97D STAND-ALONE Features External ViewFigure 1A: ENG-97D STAND-ALONE NEMA-4X en

Strona 9 - 4.3 Automatic Calibration

ENG-97D STAND-ALONEENMET Corporation43.0 Installation3.1 Mounting ControlOpen the cover and mount the instrument where desired as a CONTROL for the as

Strona 10 - 5.0 WARRANTY

ENG-97D STAND-ALONEENMET Corporation53.2 Wiring ControlThe CONTROL is supplied with a 110 VAC line cord. This may be detached and discarded if it is

Strona 11 - 680 Fairfield Court

ENG-97D STAND-ALONEENMET Corporation64.0 CalibrationCAUTION: The ENG-97D STAND-ALONE must be calibrated with the stipulated calibration gas. Although

Strona 12 - Repair Return Form

ENG-97D STAND-ALONEENMET Corporation7Calibration & ZeroingPushbutton SwitchCalibration AdapterGas CylinderCalibration CupFlow Control Valve4.2 Aut