ENMET Corporation
PO Box 979
Ann Arbor, MI 48106-0979
www.enmet.com
Manual Part Number
80003-162
MCN-13-011, 12/20/13
SE-5175
Sensor/Transmitter
Manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - SE-5175

ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 www.enmet.com Manual Part Number 80003-162 MCN-13-011, 12/20/13

Strona 2

SE-5175 ENMET Corporation 8 5.0 Maintenance The SE-5175 maintenance menus that are accessed by pressing the MENU button and entering a valid acce

Strona 3 - 1.0 Introduction

SE-5175 ENMET Corporation 9 Normal Gas Display FIGURE 6: SE-5175 Maintenance Menu Flow Chart 5ppm MENU Press and HOLD the MENU button for

Strona 4 - 2.1 SE-5175 elements

SE-5175 ENMET Corporation 10 5.1.1 Exit Maintenance Menu Exit maintenance, when the Exit appears on the display. Press the SELECT button to retu

Strona 5 - 2.3 Circuit Board Features

SE-5175 ENMET Corporation 11 5.2.1 Zero Adjust NOTE: Zero function is not used for Oxygen transmitters, proceed to Gas Span. The ZERO function m

Strona 6 - 3.0 Installation

SE-5175 ENMET Corporation 12 5.2.2 Gas Span It is recommended that the Zero Function be performed first. Do not perform a calibration unless span

Strona 7 - 3.2.1 Power Supply

SE-5175 ENMET Corporation 13 5.2.3 Alarm Set Points The SE-5175 alarm set points can be changed within limits. See Table 4 for factory set alar

Strona 8 - S/W 6.5F

SE-5175 ENMET Corporation 14 5.4 Sensor Replacement WARNING: Power must be removed from the SE-5175 before this or any internal procedure. Failu

Strona 9

SE-5175 ENMET Corporation 15 6.0 Replacement Parts ENMET replacement part numbers: Description of Part Part Number Sensor – Contact ENMET 6702

Strona 10 - 5.0 Maintenance

SE-5175 ENMET Corporation 16 8.0 WARRANTY ENMET warrants new instruments to be free from defects in workmanship and material under normal use for

Strona 11

PO Box 979 680 Fairfield Court Ann Arbor, Michigan 48106-0979 734.761.1270 Fax 734.761.3220 Returning an Instrument for Repair ENMET instrument

Strona 12 - 5.1.1 Exit Maintenance Menu

Table of Contents 1.0 INTRODUCTION...

Strona 13 - 5.2.1 Zero Adjust

Repair Return Form Mailing Address: ENMET Corporation PO Box 979 Ann Arbor, Michigan 48106 Phone Number: 734.761.1270 FAX Number: 734.

Strona 14 - 5.2.2 Gas Span

SE-5175 ENMET Corporation 1 1.0 Introduction The SE-5175 sensor/transmitter (S/T) instrument is a 3 wire, 24 VDC, 4-20mA S/T, that measures and d

Strona 15 - 5.2.4 Span Set

SE-5175 ENMET Corporation 2 2.0 Components of the SE-5175 2.1 SE-5175 elements See Figure 1 for location of elements: Feature Description Enclos

Strona 16 - Sensor Assembly

SE-5175 ENMET Corporation 3 2.3 Circuit Board Features The Display Panel is attached to the enclosure cover and is released by unscrewing the 4

Strona 17 - 6.0 Replacement Parts

SE-5175 ENMET Corporation 4 3.0 Installation The SE-5175 sensor/transmitter detects gas only at the sensor location. NOTE: Sensor Location Gas

Strona 18 - 8.0 WARRANTY

SE-5175 ENMET Corporation 5 3.2 Wiring the SE-5175 The electrical installation should conform to appropriate electrical codes, such as the Nation

Strona 19 - 680 Fairfield Court

SE-5175 ENMET Corporation 6 4.0 Operation 4.1 Start Up SE-5175 When the SE-5175 is first powered up, it goes through a series of momentary scree

Strona 20 - Repair Return Form

SE-5175 ENMET Corporation 7 4.2 Normal Display Mode When the SE-5175 is installed as described in section 3, and in clean air, the POWER green LE