6 Sensor Replacement
W
ARNING
:
Power must be removed from the EX-6100 before this or any internal procedure. Failure to do so may cause
damage to equipment, bodily injury or death.
6.1 Combustible sensor
Step1
Turn cover securing stud counter-clockwise to allow cover to open.
Step 2
Remove cover by rotating counter-clockwise
Step 3
Remove the display board - which can be left to dangle on its retaining wire. Remove the PCBs from the
support pillars and the ribbon cable from the board remaining in the enclosure.